Specifications - Net2 plus 1 door controller - Plastic housing |
|
min |
typ |
max |
units |
Electrical |
Operating voltage |
11 |
|
24 |
V DC (+20%) |
Current consumption |
|
|
200 |
mA |
Switchable current |
|
|
4 |
A |
Switchable voltage |
|
|
24 |
V DC (+20%) |
Alarm output current |
|
|
1 |
A @ 12 V DC |
Environment |
Operating temperature - Battery limits |
0 |
|
55 |
°C |
Moisture resistance |
|
None |
|
|
System Specification |
Max number of ACUs per system |
|
|
1000 |
|
Number of card holders |
|
|
50000 |
|
Number of PINs |
|
|
50000 |
|
PIN length |
4 |
|
8 |
digits |
Number of codes |
|
|
50 |
|
Code length |
4 |
|
8 |
digits |
Readers/keypads per door |
|
|
2 |
per port |
Door open time |
1 |
7 |
999999 |
sec |
Time zones |
|
|
64 |
|
Individual times within a time zone |
|
|
2000 |
|
Number of events stored on ACU |
|
|
2728 |
|
Data retention during power loss |
30 |
|
|
day(s) |
Can be used with fail OPEN release |
|
Yes |
|
|
Can be used with fail CLOSED release |
|
Yes |
|
|
Exit button input |
|
Yes |
|
|
Door contact input |
|
Yes |
|
|
Alarm/bell output |
|
Yes |
|
|
PSU monitoring input |
|
Yes |
|
|
Tamper input |
|
Yes |
|
|
Intruder alarm integration input |
|
Yes |
|
|
Wiring |
Reader cable type |
|
Belden 9540 |
|
|
RS485 data line |
|
CAT5 or Belden 8723 |
|
|
Max RS485 data line length |
|
|
1000 |
m |
Max number of ACU's per RS485 data line |
|
|
200 |
|
TCP/IP connection |
|
Yes |
|
|
Max TCP/IP nodes |
|
|
200 |
|
Ethernet network speed |
10 |
|
100 |
Mbps |
Ethernet bandwidth required |
9 |
115 |
200 |
kbps |
DHCP support |
|
Yes (static IP recommended |
|
|
Modem support |
|
Yes |
|
|
Dimensions - Control unit |
Width |
|
116 |
|
mm |
Height |
|
126 |
|
mm |
Depth |
|
25 |
|
mm |
Dimensions - Plastic housing |
Width |
|
200 |
|
mm |
Height |
|
200 |
|
mm |
Depth |
|
78 |
|
mm |