Menu

Securasound Ltd

[Javascript protected email address]    
01948 667600

Shipping

Orders for Stock items received by 3pm Monday 23rd December will be dispatched, by Royal Mail 24hr Tracked or Signed for, given the volumes in the Mail network they may not arrive until 27th December. If you need an item urgently, please call first.

Orders received after 3pm will be dispatched from 2nd January onwards.

Our offices close at 4pm on the 23rd December until 2nd January. Merry Christmas.

Ultra 64 Week Timer

Quickcode: 7293

 In Stock

£33.42 (£40.10 inc VAT)

3-4 working days

Manufacturer: Bentley Security
Part number: AT-372

Payment Methods

Payment Methods

Bentley Security

Time period 1 second to 64 weeks - accurate DIL switch time settings - 3 modes of operation - wide operating voltage.

Features:
• Working voltage 9.5 - 30V DC - auto selected by timer (no need to set input)
• “Pulse” activation after time out - option on two of the modes
• Selectable trigger and reset input polarity
• 1 second to 64 week time period. Selectable by DIL switch - crystal controlled for accurate time
• Double pole relay will switch mains - contacts rated at 8 Amps
• Three modes of operation


Setting time period - seconds, minutes, hours, days and weeks - could not be simpler - just look up the time required in the “time table” and set the DIL switch accordingly
 

Operating Mode A - trigger applied - times out and activates the relay - if auto link is fitted relay drops out after 20 seconds and is then “waiting for next trigger”
 

Operating Mode B - trigger applied – relay activates for time period then drops out. It is then ready for the next trigger.
 

Operating Mode C - once applied the trigger must remain for the duration of the time setting to activate the relay. An example of this would be monitoring a fire door. If the door is opened the timer starts (say it has been set for 3 minutes) if the door closes before the three minutes nothing happens, however if the door is open after the 3 minutes the relay will activate - if auto link is fitted relay drops out after 20 seconds and is then “waiting for next trigger”
 

Activation - trigger and reset input polarity is set by jumper links.

Input Levels for Trigger or Reset
LOW: Less than 220 ohms to ground OR an input of less than 0.8 volts
HIGH: Greater than 4700 ohms to ground OR an input of greater than 4 volts
Maximum input voltage 30V
Minimum input voltage -4V
Peak current available from either pin, 5mA

Output Levels
Double pole contacts
AC: Maximum switching voltage 250 volts, maximum current 8 Amps
(non inductive load)
DC: Maximum switching voltage 30 volts, maximum current 5 Amps
(non inductive load)
Minimum switching level 5V @ 10mA
 

Environmental Operating Conditions
Temperature range -10°C to +60°C
Maximum humidity 80% non condensing
 

Supply Voltage
Between 9.5 to 30V, automatically selected by the timer, no need to set jumpers or cut links.
 

Unit Supplied
In strong cardboard carton with 4 sticky fixers
 

Dimensions
77.9 X 47mm
 

Packing Weight
80 grams

 

01948 667600